Simple, fast and reliable spectrophotometric methods were developed for determination of Prednisolone in bulk and pharmaceutical dosage forms. The solutions of standard and the sample were prepared in Methanol. The quantitative determination of the drug was carried out using the zero order derivative values measured at 248 nm and the area under the curve method values measured at 244-252 nm (n=2). Calibration graphs constructed at their wavelength of determination were linear in the concentration range of Prednisolone using 2-10μg/ml (r²=0.9986 and r²=0.9963) for zero order and area under the curve spectrophotometric method. All the proposed methods have been extensively validated as per ICH guidelines. There was no significant difference between the performance of the proposed methods regarding the mean values and standard deviations. Developed spectrophotometric methods in this study are simple, accurate, precise and sensitive to assay of Prednisolone in tablets.